Items |
FRN0001C2S-6U Compact Inverter (VFD) for 1/8 HP Motors (Single-Phase 115 VAC) Web Price $187.00
|
FRN0001C2S-7U Compact Inverter (VFD) for 1/8 HP Motors (Single-Phase 230 VAC) Web Price $190.40
|
FRN0001C2S-2U Compact Inverter (VFD) for 1/8 HP Motors (Three-Phase 230 VAC) Web Price $178.50
|
|||
Nominal Motor HP | - 1/8 HP | |||||
Power Supply | - Single-Phase 100 to 120 V, 50/60 Hz | - Single-Phase 200 to 240 V, 50/60 Hz | - Three-Phase 200 to 240 V, 50/60 Hz | |||
Voltage / Frequency Variations (Input) | - Voltage: +10 to -10%, Frequency: +5 to -5% | - Voltage: +10 to -10%, Frequency: +5 to -5% | - Voltage: +10% to -15% (Voltage unbalance: 2% or less), Frequency: +5 to -5% | |||
Rated Current (Input) |
-
2.2 A (with DCR) 3.6 A (without DCR) |
-
1.1 A (with DCR) 1.8 A (without DCR) |
-
0.57 A (with DCR) 1.1 A (without DCR) |
|||
Required Power Supply Capacity (Input) | - 0.3 kVA | - 0.3 kVA | - 0.2 kVA | |||
Rated Capacity (Output) | - 0.26 kVA | - 0.30 kVA | - 0.30 kVA | |||
Rated Voltage (Output) | - Three-Phase 200 to 240V (With AVR) | |||||
Rated Current (Output) |
- 0.7 A | - 0.8 A (0.7 A) | - 0.8 A (0.7 A) | |||
Overload Capability (Output) | - 150% of rated current for 1 min or 200% of rated current for 0.5 sec. |
-
150% of rated current for 1 min 150% of rated current for 1 min or (200% of rated current for 0.5s (For rated current in parenthesis) |
-
150% of rated current for 1 min 150% of rated current for 1 min or (200% of rated current for 0.5s (For rated current in parenthesis) |
|||
Rated Frequency (Output) | - 50, 60 Hz | |||||
Maximum Output Frequency |
-
Adjustable up to 400 Hz. However, when using with Oriental Motor or Brother Gearmotors, limit the motor output speed to 120 Hz (3,600 r/min). |
|||||
Torque % (Braking) | - 150 | |||||
DC Injection Braking (Brake) | - Starting Frequency: 0.0 to 60.0 Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% | |||||
Braking Transistor (Brake) | - | |||||
Motor Control Method |
-
Induction Motor: V/f, Dynamic Torque Vector, Slip Comp, Auto-Torque Boost, Automatic Energy Savings Synchronous Motor (PMAC): Sensorless Magnetic Positioning [speed control range: 10% of base frequency and up] |
|||||
Protocol | - Modbus RTU Mode / RS-485 Port | |||||
Analog Inputs |
-
0 to +10 VDC 0 to 20mA or 4 to 20 mA |
|||||
Digital Inputs | - Qty 5: Programmable | |||||
Input Power Supply | - 24 VDC 50 mA Max | |||||
Analog Outputs | - Qty 1: 0 to +10VDC, User Selectable Proportional Analog Signal Functionality | |||||
Digital Outputs |
-
Qty 1: Form C (1N.O. & 1N.C.) Dry Contacts Rated 0.3A at 230V Max, User Selectable Functionality Qty 1: Transistor Output Rated 50mA at 27Vdc Max, User Selectable Functionality |
|||||
Applicable Safety Standards | - UL508C | - UL508C, EN 61800-5-1:2007 | - UL508C, EN 61800-5-1:2007 | |||
Enclosure | - IP20 (IEC 60529:1989) / UL open type (UL50) | |||||
Cooling Method | - Natural Cooling | |||||
Ambient Temperature |
-
+14 to +122ºF (-10 to +50ºC) - UL Open Type +14 to +104ºF (-10 to +40ºC) - UL Type 1 |
|||||
Storage Temperature | - -13 to +158ºF (-25 to +70ºC) | |||||
Humidity | - 5% to 95% With No Condensation | |||||
Altitude | - 0 to 3,300 ft. (1,000 m) Without Derating, Derate Output Current for Higher Altitudes per User's Manual | |||||
|