Available to Ship1 | - {Contact your local sales office for more information.} |
Power Input |
- Single-Phase 200-230 VAC / Three-Phase 200-230 VAC |
Motor Output Power |
- 100 W (1/8 HP) 200 W (1/4 HP) 50 W (1/15 HP) |
Voltage and Frequency |
- -15% to +10% 50/60 Hz |
DC Control Power Supply |
- 24 VDC ±10% 0.8 A |
Rated Input Current2 |
-
2.8 A (Single-Phase 200-230 VAC) 1.6 A (Three-Phase 200-230 VAC) |
Interface |
- Pulse, Analog Speed Command Voltage, Analog Torque Command Voltage |
Maximum Input Pulse Frequency |
-
Line driver output by programmable controller: 500kHz (When pulse duty is 50%) Open collector output by porgrammable controller: 250 kHz (When pulse duty is 50%) |
Protective Function |
-
When the following protective functions are activated, an alarm signal is output and the motor is stopped. Overflow, Overcurrent Protection, Overheat Protection, Overvoltage Protection, Main Power Supply Error, Undervoltage, Motor Overheat Protection, Sensor Error during Operation, Encoder Communication Error, Overload, Overspeed, Position Range Error, Absolute Position Loss, Command Pulse Error, EEPROM Error, Sensor Error during Initialization, Rotor Rotation during Initialization, Encoder EEPROM Error, Motor Combination Error, ABS Not Supported, No Battery, Regeneration Unit Overheat, Electronic Gear Setting Error |
Input Signal |
-
|
Output Signal |
-
|
Other Functions |
-
Position Control, Speed Control, Torque Control, Tension Control Automatic Tuning, Damping Control Function (7 to 30 Hz), Position Preset Function, Current Position Output Function, Torque Limiting Function Pulse Input Mode (2-Pulse Input, 1-Pulse Input), Analog Monitor Output Function (Speed, Torque), Absolute System Enabled/Disabled Warning Output Function, (Overflow, Overheat, Overvoltage, Main Power Supply, Undervoltage, Battery Undervoltage, Overload, Overspeed, Absolute Position Loss, Electronic Gear Setting Error) |
Extended Functions |
- When using the control module OPX-2A (sold separately) or the data setting software MEXE02 (free download) |
Insulation Resistance |
-
100 MΩ min when measured with a 500 VDC megger between the following locations:
|
Dielectric Voltage |
-
No abnormality is judged with the following application for 1 minute:
|
Ambient Temperature (Driver) |
- 0 ~ +50ºC (32 ~ 122ºF) (non-freezing) |
Ambient Humidity |
- 85% max. (non-condensing) |
Operating Atmosphere |
- No corrosive gases or dust. The product should not be exposed to water, oil or other liquids. |
Degree of Protection |
- IP20 |
|