Oriental Motor

ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)

Print Back
Centrifugal fans / centrifugal blowers move air by means of the centrifugal force generated by rotating a cylindrical runner on which blades have been arranged. Centrifugal blowers have a small outlet, which concentrates air in a single direction, and are therefore suitable for local cooling. They also create large static pressure, making them optimal for cooling equipment through which air cannot flow easily and for airflow through ducts.
  • Impeller Diameter 3.15 in. (80 mm)
  • Max. Air Flow 63.5 CFM (1.8 m3/min)
pcj_mb840-b
Unit of Measure
Items pcj_mb840-b
MB840-B
3.15 in. (80 mm) MB Series Centrifugal Fan / Blower (Single-Phase 100/110/115 VAC)
Web Price $88.00
pcj_mb840-b
MB840-D
3.15 in. (80 mm) MB Series Centrifugal Fan / Blower (Single-Phase 200/220/230 VAC)
Web Price $91.00
pcj_mb840-b
MB840-T
3.15 in. (80 mm) MB Series Centrifugal Fan / Blower (Three-Phase 200/220/230 VAC)
Web Price $91.00
f3_tmb840bg
T-MB840-B-GA
3.15 in. (80 mm) MB Series Centrifugal Fan / Blower Kit (Single-Phase 100/110/115 VAC)
Web Price $106.00
f3_tmb840bg
T-MB840-D-GA
3.15 in. (80 mm) MB Series Centrifugal Fan / Blower Kit (Single-Phase 200/220/230 VAC)
Web Price $110.00
Impeller Diameter - 3.15 in.
Power Supply - Single-Phase 100/110/115 VAC - Single-Phase 200/220/230 VAC - Three-Phase 200/220/230 VAC - Single-Phase 100/110/115 VAC - Single-Phase 200/220/230 VAC
Current (A) - 0.29 [100 VAC, 50 Hz]
0.37 [100/110/115 VAC, 60 Hz]
- 0.14 [200 VAC, 50 Hz]
0.18 [200/220/230 VAC, 60 Hz]
0.15 [230 VAC, 50 Hz]
- 0.12 [200 VAC, 50 Hz]
0.15 [200/220/230 VAC, 60 Hz]
- 0.29 [100 VAC, 50 Hz]
0.37 [100/110/115 VAC, 60 Hz]
- 0.14 [200 VAC, 50 Hz]
0.18 [200/220/230 VAC, 60 Hz]
0.15 [230 VAC, 50 Hz]
Speed (r/min) - 2800 [100 VAC, 50 Hz]
3150 [100 VAC, 60 Hz]
3300 [110 VAC, 60 Hz]
3350 [115 VAC, 60 Hz]
- 2800 [200 VAC, 50 Hz]
2850 [230 VAC, 50 Hz]
3200 [200 VAC, 60 Hz]
3350 [220/230 VAC, 60 Hz]
- 2800 [200 VAC, 50 Hz]
3200 [200 VAC, 60 Hz]
3350 [220/230 VAC, 60 Hz]
- 2800 [100 VAC, 50 Hz]
3150 [100 VAC, 60 Hz]
3300 [110 VAC, 60 Hz]
3350 [115 VAC, 60 Hz]
- 2800 [200 VAC, 50 Hz]
2850 [230 VAC, 50 Hz]
3200 [200 VAC, 60 Hz]
3350 [220/230 VAC, 60 Hz]
Max. Air Flow - 56.5 CFM [100 VAC, 50 Hz]
63.5 CFM [100/110/115 VAC, 60 Hz]  
- 56.5 CFM [200/230 VAC, 50 Hz]
63.5 CFM [200/220/230 VAC, 60 Hz]  
- 56.5 CFM [200 VAC, 50 Hz]
63.5 CFM [200/220/230 VAC, 60 Hz]  
- 56.5 CFM [100 VAC, 50 Hz]
63.5 CFM [100/110/115 VAC, 60 Hz]  
- 56.5 CFM [200/230 VAC, 50 Hz]
63.5 CFM [200/220/230 VAC, 60 Hz]  
Max. Static Pressure - 0.61 inH2O [100 VAC, 50 Hz]
0.886 inH2O [100 VAC, 60 Hz]
0.906 inH2O [110/115 VAC, 60 Hz]  
- 0.61 inH2O [200 VAC, 50 Hz]
0.63 inH2O [230 VAC, 50 Hz]
0.886 inH2O [200 VAC, 60 Hz]
0.906 inH2O [220/230 VAC, 60 Hz]  
- 0.61 inH2O [200 VAC, 50 Hz]
0.886 inH2O [200 VAC, 60 Hz]
0.906 inH2O [220/230 VAC, 60 Hz]  
- 0.61 inH2O [100 VAC, 50 Hz]
0.886 inH2O [100 VAC, 60 Hz]
0.906 inH2O [110/115 VAC, 60 Hz]  
- 0.61 inH2O [200 VAC, 50 Hz]
0.63 inH2O [230 VAC, 50 Hz]
0.886 inH2O [200 VAC, 60 Hz]
0.906 inH2O [220/230 VAC, 60 Hz]  
Noise Level - 55 dB (A) [100 VAC, 50 Hz]
58 dB (A) [100 VAC, 60 Hz]
59 dB (A) [110/115 VAC, 60 Hz]
- 55 dB (A) [200/230 VAC, 50 Hz]
58 dB (A) [200 VAC, 60 Hz]
59 dB (A) [220/230 VAC, 60 Hz]
- 55 dB (A) [200 VAC, 50 Hz]
58 dB (A) [200 VAC, 60 Hz]
59 dB (A) [220/230 VAC, 60 Hz]
- 55 dB (A) [100 VAC, 50 Hz]
58 dB (A) [100 VAC, 60 Hz]
59 dB (A) [110/115 VAC, 60 Hz]
- 55 dB (A) [200/230 VAC, 50 Hz]
58 dB (A) [200 VAC, 60 Hz]
59 dB (A) [220/230 VAC, 60 Hz]
Fan Kit - Fan Only - Fan Only - Fan Only - Fan, Finger Guard, Mounting Bracket, Mounting Screws - Fan, Finger Guard, Mounting Bracket, Mounting Screws
Safety Standards - UL CSA CE - UL CSA CE - UL CSA CE - UL CSA EN CE - UL CSA EN CE