Oriental Motor

ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)

Print Back
Centrifugal fans / blowers maximize static pressure to provide concentrated airflow in one defined direction. These blowers can be used in a fixed position or mounted on moving parts, and are optimal for local cooling and airflow through ducts.

Unit of Measure

Specifications

Lead Time1 - {Contact your local sales office for more information.}

Fan Type

- Centrifugal Fan / Blower

Impeller Diameter

- 6.30 in.

Power Supply

- Three-Phase 200/220/230 VAC

Current (A)

- 1.80

Speed (r/min)

- 2750 [200 VAC, 50 Hz]
3100 [200 VAC, 60 Hz]
3200 [230 VAC, 60 Hz]

Max. Air Flow

- 282 CFM [200 VAC, 50 Hz]
318 CFM [200/230 VAC, 60 Hz]  

Max. Static Pressure

- 1.96 inH2O [200 VAC, 50 Hz]
2.75 inH2O [200/230 VAC, 60 Hz]  

Noise Level

- 76 dB (A) [200 VAC, 50 Hz]
80 dB (A) [200/230 VAC, 60 Hz]

Fan Kit

- Fan Only

RoHS Compliant

- Yes

Safety Standards

- UL CSA

Insulation Resistance

- 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

- Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

- 81ºF (45ºC) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

- Class B (266ºF [130ºC])

Overheat Protection

- Built-in thermal protector (automatic reset type)
Operating temperature, open: 266ºF±9ºF (130ºC±5ºC), close: 181.4ºF±27ºF (83ºC±15ºC)

Ambient Temperature Range

- 14ºF ~ 122ºF (-10ºC ~ 50ºC)

Ambient Humidity

- 85% or less (noncondensing)

Dimensions


 

Airflow


 

System


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.