Frame Size
|
-
3.54 in90 mm
|
Motor Length
|
-
5.67 in.144 mm
|
Driver Voltage Input Power
|
-
AC
|
Speed-Torque Characteristics
|
-

|
Holding Torque
|
-
1416 oz-in10 N·m
|
Holding Torque at Motor Standstill
|
-
708 oz-in5 N·m
|
Type
|
-
Mechanical Absolute Encoder
|
Shaft/Gear Type
|
-
Planetary Gear, Non-Backlash
|
Gear Ratio (X:1)
|
-
5 :1
|
Lost Motion
|
-
2 arcmin or less (±0.3 N·m)
|
Shaft
|
-
Single
|
Electromagnetic Brake
|
-
Not Equipped
|
Connection Type
|
-
Connector
|
Resolution (Resolution Setting: 1000 P/R)
|
-
0.072 °/Pulse
|
Permissible Speed Range (r/min)
|
-
0 ~ 600
|
Rotor Inertia
|
-
5.96 oz-in²1090x10-7 kg·m²
|
Stop Position Accuracy
|
-
±3 arc minutes (±0.05º)
|
Shaft Runout
|
-
0.05 mm (0.002 in.) T.I.R.
|
Concentricity
|
-
0.075 mm (0.003 in.) T.I.R.
|
Perpendicularity
|
-
0.075 mm (0.003 in.) T.I.R.
|
Permissible Overhung Load
|
-
0 in.from Shaft End = 14.6 lb0.2 in. from Shaft End = 15.4 lb0.39 in. from Shaft End = 16.1 lb0.59 in. from Shaft End = 16.9 lb0.79 in. from Shaft End = 24.8 lb0 mm from Shaft End = 370 N5 mm from Shaft End = 390 N10 mm from Shaft End = 410 N15 mm from Shaft End = 430 N20 mm from Shaft End = 460 N
|
Permissible Thrust Load
|
-
134 lb600 N
|
RoHS Compliant
|
-
These products do not contain substances that exceed the regulation values in the RoHS Directive.
|
Safety Standards
|
-
UL CE
|
California Proposition 65
|
-
⚠ CA WARNING Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov See "?" or copy/paste www.P65Warnings.ca.gov in your browser.
|
Insulation Class
|
-
Class B [130ºC (266ºF)] [Recognized as 105 (A) by UL.]
|
Insulation Resistance
|
-
100 MΩ or more when 500 VDC megger is applied between the following places: Case - Motor and sensor windings
|
Dielectric Strength
|
-
Sufficient to withstand the following for 1 minute: Case - Motor and sensor windings 1.5 kVAC 50 Hz or 60 Hz
|
Ambient Temperature
|
-
0 ~ 40ºC (32 ~ 104ºF) (non-freezing)
|
Ambient Humidity
|
-
85% or less (Non-condensing)
|
Degree of Protection
|
-
IP66 (excluding the mounting surface and the connector on the driver side of the connecting cable when connected)
|