COMPANY HEADER
Request Information
Please contact technical support for the replacement option. This part number is scheduled to be discontinued.

Fan Kit

Unit of Measure

Return Policy

N/A This product cannot be cancelled or returned once the order has been processed.

Product Line

N/A ORIX®

Fan Type

N/A Axial Flow

Frame Size

N/A 5.51 in140 mm

Power Supply

N/A Three-Phase 220/230 VAC

Frequency

N/A 50 Hz60 Hz

Current

N/A 0.08 A [200 VAC, 50 Hz] 0.09 A [200/220/230 VAC, 60 Hz]

Function

N/A None

Connection Type

N/A Terminal Box

Speed (r/min)

N/A 2600 [200 VAC, 50 Hz]
2650 [200 VAC, 60 Hz]
2900 [220 VAC, 60 Hz]
2950 [230 VAC, 60 Hz]

Max. Air Flow

N/A 159 CFM [200 VAC, 50 Hz]
162 CFM [200 VAC, 60 Hz]
177 CFM [220/230 VAC, 60 Hz]  
4.5 m3/min [200 VAC, 50 Hz]
4.6 m3/min [200 VAC, 60 Hz]
5.0 m3/min [220/230 VAC, 60 Hz]  

Max. Static Pressure

N/A 0.369 inH2O [200 VAC, 50 Hz]
0.325 inH2O [200 VAC, 60 Hz]
0.43 inH2O [220 VAC, 60 Hz]
0.437 inH2O [230 VAC, 60 Hz]  
92 Pa [200 VAC, 50 Hz]
81 Pa [200 VAC, 60 Hz]
107 Pa [220 VAC, 60 Hz]
109 Pa [230 VAC, 60 Hz]  

Noise Level

N/A 48 dB [A] [200 VAC, 50 Hz]
49 dB [A] [200 VAC, 60 Hz]
51 dB [A] [220/230 VAC, 60 Hz]

Components

N/A MRS14-TUL (Fan Unit)
FG14D (Finger Guard)
M4 x 16 mm (0.63 in.) (Mounting Screws)

Fan Kit

N/A Fan, Finger Guard, Mounting Screws

RoHS Compliant

N/A Yes

Safety Standards

N/A cUL EN CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

N/A 54ºF (30ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

N/A Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

N/A Built-in thermal protector (automatic reset type)
Operating temperature, open: 248ºF±9ºF (120ºC±5ºC), close: 170.6ºF±27ºF (77ºC±15ºC)

Ambient Temperature Range

N/A 14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

N/A 85% or less (noncondensing)