COMPANY HEADER
Request Information
This item has been discontinued. Please contact our technical support team for a replacement.
Unit of Measure

Return Policy

N/A This product cannot be cancelled or returned once the order has been processed.

Product Line

N/A Oriental Motor®

Motor Type

N/A Reversible

Frame Size

N/A 3.54 in90 mm

Output Power

N/A 60 W (1/12 HP)

Voltage (VAC)

N/A Single-Phase 110/115 VAC

Frequency (Hz)

N/A 60

Current

N/A 1.13 A [110 VAC] 1.17 A [115 VAC]

Type

N/A Cable

Electromagnetic Brake

N/A Equipped

Shaft/Gear Type

N/A Round Shaft (No Gearhead)

Output Shaft Diameter

N/A 12 mm

Rated Torque

N/A 3.063 lb-in  0.35 N·m  

Rated Speed (rpm)

N/A 1650

Permissible Load Inertia

N/A 6 oz-in²1.1 x; 10-4 kg·m²

Permissible Overhung Load

N/A 0.39 in. from Output Shaft End = 54 lb0.79 in. from Output Shaft End = 60 lb10 mm from Output Shaft End = 240 N20 mm from Output Shaft End = 270 N

Permissible Thrust Load

N/A Avoid axial load as much as possible. If axial load is unavoidable, keep it to half or less of the motor mass.

RoHS Compliant

N/A These products do not contain substances that exceed the regulation values in the RoHS Directive.

Safety Standards

N/A UL CE

CE Marking

N/A Low Voltage Directives

Insulation Resistance

N/A 100 MΩ or more when 500 VDC megger is applied between the windings and the case after rated operation under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50 Hz or 60 Hz applied between the windings and the case for 1 minute after rated operation under normal ambient temperature and humidity.

Temperature Rise

N/A Temperature rise of windings are 144ºF (80ºC) or less measured by the resistance change method after rated operation under normal ambient temperature and humidity with 200 mm x 200 mm x 5mm Aluminum heat sink.

Insulation Class

N/A 130 (B)

Overheat Protection

N/A Built-in thermal protector (automatic return type). Open: 266 ± 9ºF (130 ± 5ºC) Close: 185 ± 36ºF (85 ± 20ºC)

Ambient Temperature Range

N/A 14ºF ~ 104ºF (-10ºC ~ 40ºC) (nonfreezing)

Ambient Humidity

N/A 85% or less (noncondensing)

Degree of Protection

N/A IP20

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Voltage (Brake)

N/A Single-Phase 110/115 VAC

Current (Brake)

N/A 0.09 A

Input

N/A 7 W

Static Friction Torque

N/A 71 oz-in0.5 N·m

Braking Characteristics

N/A