COMPANY HEADER
Request Information
This item has been discontinued. This product is available as a motor and gearhead separate purchase. Please contact technical support.

High-Performance KII Series

High-Performance KII Series

Replacement Motor

Unit of Measure

Return Policy

N/A This product cannot be cancelled or returned once the order has been processed.

Product Line

N/A Oriental Motor®

Motor Type

N/A Induction

Frame Size

N/A 3.54 in90 mm

Output Power

N/A 90 W (1/8 HP)

Voltage (VAC)

N/A Single-Phase 110/115 VAC

Frequency (Hz)

N/A 60

Current

N/A 1.44 A

Electromagnetic Brake

N/A Not Equipped

Type

N/A Terminal Box

Shaft/Gear Type

N/A Parallel Shaft Gearhead

Gear Ratio (X:1)

N/A 9 :1

Output Shaft Diameter

N/A 18 mm

Rated Torque

N/A 41 lb-in  4.7 N·m  

Rated Speed (rpm)

N/A 200

Permissible Load Inertia

N/A 486 oz-in²89.1 x 10-4 kg·m²

Permissible Overhung Load

N/A 0.39 in. from Shaft End = 90 lb0.79 in. from Shaft End = 112 lb10 mm from Shaft End = 400 N20 mm from Shaft End = 500 N

Permissible Thrust Load

N/A 33 lb150 N

Components

N/A 5IK90GVR-UAT2 [Motor] 5GVR9B [Gearhead]

RoHS Compliant

N/A Yes

Safety Standards

N/A UL CCC CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50 Hz or 60 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity.

Temperature Rise

N/A Temperature rise of windings are 144ºF (80ºC) or less measured by the resistance change method after rated operation under normal ambient temperature and humidity.

Thermal Class

N/A 130 (B)

Overheat Protection

N/A Built-in thermal protector (automatic return type). Open: 266 ± 9ºF (130 ± 5ºC) Close: 185 ± 36ºF (85 ± 20ºC)

Ambient Temperature Range

N/A 14ºF ~ 104ºF (-10ºC ~ 40ºC) (nonfreezing)

Ambient Humidity

N/A 85% or less (noncondensing)

Degree of Protection

N/A IP54