COMPANY HEADER
Request Information
This product has been discontinued, please contact your local sales office for more information.
Unit of Measure

Return Policy

N/A This product cannot be cancelled or returned once the order has been processed.

Product Line

N/A ORIX®

Fan Type

N/A Axial Fan

Frame Size

N/A 7.09 in180 mm

Power Supply

N/A Single-Phase 110/115 VAC

Frequency

N/A 50 Hz60 Hz

Current

N/A 1.2 A [100 VAC, 50 Hz] 1.4 A [100/115 VAC, 60 Hz]

Function

N/A Variable Flow

Connection Type

N/A Terminal Box

Speed (r/min)

N/A 1000 ~ 2800 [100 VAC, 50Hz]
750 ~ 3200 [100 VAC, 60 Hz]
1100 ~ 3350 [115 VAC, 60 Hz]

Max. Air Flow

N/A 138 ~ 388 CFM [100 VAC, 50 Hz]
98.8 ~ 424 CFM [100 VAC, 60 Hz]
141 ~ 452 CFM [115 VAC, 60 Hz]  
3.9 ~ 11.0 m3/min [100 VAC, 50 Hz]
2.8 ~ 12.0 m3/min [100 VAC, 60 Hz]
4.0 ~ 12.8 m3/min [115 VAC, 60 Hz]  

Max. Static Pressure

N/A 0.0786 ~ 0.746 inH2O [100 VAC, 50 Hz]
0.0472 ~ 0.786 inH2O [100 VAC, 60 Hz]
0.0942 ~ 1.02 inH2O [115 VAC, 60 Hz]  
19.6 ~ 186 Pa [100 VAC, 50 Hz]
11.8 ~ 196 Pa [100 VAC, 60 Hz]
23.5 ~ 255 Pa [115 VAC, 60 Hz]  

Noise Level

N/A 40 dB (A) [750 r/min]
61 dB (A) [3350 r/min]

Fan Kit

N/A Fan Only

RoHS Compliant

N/A Yes

Safety Standards

N/A UL CSA EN CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

N/A 54ºF (30ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

N/A Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

N/A Built-in thermal protector (automatic reset type)
Operating temperature, open: 248ºF±9ºF (120ºC±5ºC), close: 170.6ºF±27ºF (77ºC±15ºC)

Ambient Temperature Range

N/A 14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

N/A 85% or less (noncondensing)