COMPANY HEADER
Request Information
This item has been discontinued. Please contact our technical support team for a replacement.

Fan Kit

Unit of Measure

Return Policy

N/A This product cannot be cancelled or returned once the order has been processed.

Fan Type

N/A Centrifugal Blower

Impeller Diameter

N/A 1.97 in.50 mm

Power Supply

N/A Single-Phase 100/110/115 VAC

Current (A)

N/A 0.11 [100 VAC, 50 Hz, 110/115 VAC, 60 Hz]
0.10 [100 VAC, 60 Hz]

Speed (r/min)

N/A 2600 [100 VAC, 50 Hz]
3000 [100 VAC, 60 Hz]
3200 [110/115 VAC, 60 Hz]

Max. Air Flow

N/A 7.41 CFM [100 VAC, 50 Hz]
8.47 CFM [100 VAC, 60 Hz]
8.83 CFM [110/115 VAC, 60 Hz]  
0.21 m3/min [100 VAC, 50 Hz]
0.24 m3/min [100 VAC, 60 Hz]
0.25 m3/min [110/115 VAC, 60 Hz]  

Max. Static Pressure

N/A 0.149 inH2O [100 VAC, 50 Hz]
0.213 inH2O [100 VAC, 60 Hz]
0.221 inH2O [110/115 VAC, 60 Hz]  
37 Pa [100 VAC, 50 Hz]
53 Pa [100 VAC, 60 Hz]
55 Pa [110/115 VAC, 60 Hz]  

Noise Level

N/A 33 dB (A) [100 VAC, 50 Hz]
37 dB (A) [100 VAC, 60 Hz]
38 dB (A) [110/115 VAC, 60 Hz]

Components

N/A MB520-B (Fan Unit)
PAS2B (Mounting Bracket)
M4 x 10 mm (0.39 in.) (Mounting Screws)

Fan Kit

N/A Fan, Mounting Bracket, Mounting Screws

RoHS Compliant

N/A Yes

Safety Standards

N/A UL CSA EN CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

N/A 81ºF (45ºC) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

N/A Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

N/A Impedance protection

Ambient Temperature Range

N/A 14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

N/A 85% or less (noncondensing)