Axial fans use a propeller to create a flow of air the direction of the axis of rotation. Because they create a large airflow, axial fans are optimal for a wide variety of cooling and other airflow needs.
  • 100,000 hour life expectancy
Unit of Measure
Lead Time1 N/A {Contact your local sales office for more information.}

Product Line

N/A ORIX®

Fan Type

N/A Axial Fan

Frame Size

N/A 6.77 in172 mm

Thickness

N/A 2.01 in.51 mm

Power Supply

N/A 24 VDC

Current

N/A 0.58

Type

N/A E Type (Long Life)

Function

N/A Stall Alarm - Electronic

Connection Type

N/A Lead Wire

Speed (r/min)

N/A 3050

Max. Air Flow

N/A 226 CFM  6.4 m3/min  

Max. Static Pressure

N/A 0.55 inH2O  137.2 Pa  

Noise Level

N/A 47 db (A)

RoHS Compliant

N/A These products do not contain substances that exceed the regulation values in the RoHS Directive.

Safety Standards

N/A TUV UL CSA

CE Marking

N/A EMC Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 10 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 500 VAC at 50 Hz or 60 Hz applied between the windings and the frame for 1 minute after continuous operation under normal ambient temperature and humidity

Overheat Protection

N/A Equipped with a built-in burnout protection circuit

Ambient Temperature Range

N/A -4ºF ~ 158ºF (-20ºC ~ 70ºC)

Alarm Type

N/A Electronic

Alarm Activation Speed

N/A When locked

Output Mode

N/A Open-collector output

Output Condition

N/A Operation: L level (Internal transistor ON)
When locked: H level (Internal transistor OFF)

Maximum Rating

N/A Maximum applied voltage: 27.6 VDC max.
Maximum current: 5 mA max.

Delay Function

N/A Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 1 second.

Circuit Connection

N/A
Circuit Connection


 


 


 


 

 