The αSTEP AZ Series multi-axis controller / driver supports EtherCAT communication. Compatible with the CiA402 drive profile. It can be connected to the αSTEP AZ Series DC input motors and electric actuators.
Drivers
Drivers
Drivers
Drivers
Drivers
Drivers
Drivers
Drivers
Drivers
Drivers
Lead Time1 | Contact your local sales office. |
Return Policy |
- This product cannot be cancelled or returned once the order has been processed. |
Product Line |
- Oriental Motor® |
Driver Type |
- Closed Loop, Absolute, Multi-Axis |
Number of Axes |
- 3-axis |
Power Supply |
- 24/48 VDC |
Current |
-
7.0 A When using a motor make sure that the average is 4.0 A max. |
Control Power Supply |
- 24 VDC |
Control Current |
-
1.5 A When using an electromagentic brake, use a 24 VDC ±5% power supply to electromagnetic brake. When using an electromagnetic brake with a 20 m (65.6 ft.) connection cable, us a 24 VDC ±4% power supply, |
Degree of Protection |
- IP10 |
Operating Environment |
-
Ambient Temperature: 0 to 50ºC (32 ~ 122ºF) (non-freezing) Humidity: 85% or less (non-condensing) Altitude: 1000 m (3280 ft.) max. above sea level Atmosphere: Use in an area without corrosive gases and dust. This product should not be exposed to water or oil. |
Storage Condition |
-
Ambient Temperature: -25 to 70ºC (-13 ~ 158ºF) (non-freezing) Humidity: 85% or less (non-condensing) Altitude: 3000 m (9842 ft.) max. above sea level Atmosphere: Use in an area without corrosive gases and dust. This product should not be exposed to water or oil. |
Insulation Resistance |
-
The measured value is 100 MΩ or more when a 500 VDC megger is applied between the following places: Between FG terminal and Power Supply terminal |
Dielectric Strength |
-
Sufficient to withstand the following for 1 minute: Between FG terminal and Power Supply terminal 1 kVAC 50/60 Hz Leakage current 10 mA max. |
Baud Rate |
- 100MBps |
Communication Period |
- 0.5ms/1ms/2ms/3ms/4ms/5ms/6ms/7ms/8ms |
Node Address |
- 0~255 (00h~FFh, initial value:00h) |
Communication Protocol |
-
EtherCAT dedicated protocol(CoE) CiA402 drive profile |
|
|
|