| Lead Time1 | N/A {Contact your local sales office for more information.} |
Product Line |
N/A Oriental Motor® |
Motor Type |
N/A Induction |
Frame Size |
N/A 4.09 in104 mm |
Output Power |
N/A 200 W (1/4 HP) |
Voltage (VAC) |
N/A Single-Phase 220/230 VAC |
Frequency (Hz) |
N/A 60 50 |
Current |
N/A 1.5 A |
Shaft/Gear Type |
N/A Round Shaft (No Gearhead) |
Output Shaft Diameter |
N/A 14 mm |
Electromagnetic Brake |
N/A Not Equipped |
Rated Torque |
N/A 11.25 lb-in [60 Hz] 13.125 lb-in [50 Hz] 1.27 N·m [60 Hz] 1.52 N·m [50 Hz] |
Rated Speed (rpm) |
N/A 1500 [60 Hz] 1250 [50 Hz] |
Permissible Overhung Load |
N/A 0.39 in. from Shaft End = 72 lb0.79 in. from Shaft End = 78 lb10 mm from Shaft End = 320 N20 mm from Shaft End = 350 N |
Permissible Thrust Load |
N/A Avoid thrust load as much as possible. If thrust load is unavoidable, keep it to half or less of the motor mass. |
RoHS Compliant |
N/A Yes |
Safety Standards |
N/A UL CSA CCC CE |
CE Marking |
N/A Low Voltage Directives |
California Proposition 65 |
N/A
⚠ CA WARNING Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov See "?" or copy/paste www.P65Warnings.ca.gov in your browser. |
Insulation Resistance |
N/A 100 MΩ or more when 500 VDC is applied between the windings and the case after rated motor operation under normal ambient temperature and humidity. |
Dielectric Strength |
N/A Sufficient to withstand 1.5 kVAC at 50 Hz or 60 Hz applied between the windings and the case for 1 minute after rated motor operation under normal ambient temperature and humidity. |
Temperature Rise |
N/A Temperature rise of windings are 126ºF (70ºC) or less measured by the resistance change method after rated motor operation with connection to aluminum heat radiation plate (9.06 in. x 9.06 in.) (0.20 in. thickness). |
Insulation Class |
N/A Class B (266ºF [130ºC]) |
Overheat Protection |
N/A Built-in thermal protector (Automatic return type). Operating temperature, open: 302ºF ± 9ºF (150ºC ± 5ºC) close: 204.8ºF ± 27ºF (96ºC ± 15ºC) |
Ambient Temperature Range |
N/A 14ºF ~ 104ºF (-10ºC ~ 40ºC) (non-freezing) |
Ambient Humidity |
N/A 85% or less (Non-condensing) |
Degree of Protection |
N/A IP40 |
|
|
|
|
|
|
|
|