| Lead Time1 | N/A {Contact your local sales office for more information.} |
Product Line |
N/A Oriental Motor® |
Motor Type |
N/A Induction |
Frame Size |
N/A 4.33 in110 mm |
Output Power |
N/A 200 W (1/4 HP) |
Voltage (VAC) |
N/A Three-Phase 380/400/415 VAC |
Frequency (Hz) |
N/A 60 50 |
Current |
N/A
0.56 A [380/400 VAC, 50 Hz] 0.52 A [380 VAC, 60 Hz] 0.51 A [400 VAC, 60 Hz] 0.57 A [415 VAC, 50 Hz] |
Type |
N/A Terminal Box |
Electromagnetic Brake |
N/A Not Equipped |
Shaft/Gear Type |
N/A Parallel Shaft Gearhead |
Gear Ratio (X:1) |
N/A 50 :1 |
Output Shaft Diameter |
N/A 22 mm |
Rated Torque |
N/A 430 lb-in [60 Hz] 510 lb-in [50 Hz] 48.6 N·m [60 Hz] 58.1 N·m [50 Hz] |
Rated Speed (rpm) |
N/A 30 r/min [50 Hz] 36 r/min [60 Hz] |
Permissible Load Inertia |
N/A 51000 oz-in²9300 x 10-4 kg·m² |
Permissible Overhung Load |
N/A 0.39 in. from Shaft End = 315 lb0.79 in. from Shaft End = 382 lb10 mm from Shaft End = 1400 N20 mm from Shaft End = 1700 N |
Permissible Thrust Load |
N/A 90 lb400 N |
Components |
N/A
7GV50BS, GV Series Parallel Shaft Gearhead (50:1 Gear Ratio, Stainless Steel Shaft) ($278.00) 7IK200VGV-EU3T2, 200 W (1/4 HP) KII / KIIS Series AC Motor & Gear Motors Induction Pinion Shaft Motor () ($351.00) |
RoHS Compliant |
N/A These products do not contain substances that exceed the regulation values in the RoHS Directive. |
Safety Standards |
N/A UL CCC CE |
CE Marking |
N/A Low Voltage Directives |
California Proposition 65 |
N/A
⚠ CA WARNING Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov See "?" or copy/paste www.P65Warnings.ca.gov in your browser. |
Insulation Resistance |
N/A 100 MΩ or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. |
Dielectric Strength |
N/A Sufficient to withstand 1.5 kV at 50 Hz or 60 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity. |
Temperature Rise |
N/A Temperature rise of the windings is 144ºF (80ºC) or less measured by the resistance change method after rated load continuous operation under normal ambient temperature and humidity. |
Thermal Class |
N/A 130 (B) |
Ambient Temperature Range |
N/A 0ºC ~ 40ºC (32ºF ~140ºF) (nonfreezing) |
Ambient Humidity |
N/A 85% or less (noncondensing) |
Degree of Protection |
N/A IP66 |
|
|
|
|
|
|