Centrifugal fans / blowers maximize static pressure to provide concentrated airflow in one defined direction. These blowers can be used in a fixed position or mounted on moving parts, and are optimal for local cooling and airflow through ducts.
  • Fan kit features centrifugal blower, mounting bracket, filter and mounting screws in a single package.

Fan Kits

Unit of Measure
Lead Time1 N/A {Contact your local sales office for more information.}

Fan Type

N/A Centrifugal Blower

Impeller Diameter

N/A 3.94 in.100 mm

Power Supply

N/A Single-Phase 100/110/115 VAC

Current (A)

N/A 0.50 [100 VAC, 50 Hz]
0.55 [100/110/115 VAC, 60 Hz]

Speed (r/min)

N/A 2750 [100 VAC, 50 Hz]
3050 [100 VAC, 60 Hz]
3200 [110/115 VAC, 60 Hz]

Max. Air Flow

N/A 81.2 CFM [100 VAC, 50 Hz]
91.8 CFM [100/110/115 VAC, 60 Hz]  
2.3 m3/min [100 VAC, 50 Hz]
2.6 m3/min [100/110/115 VAC, 60 Hz]  

Max. Static Pressure

N/A 0.826 inH2O [100 VAC, 50 Hz]
1.14 inH2O [100/110/115 VAC, 60 Hz]  
206 Pa [100 VAC, 50 Hz]
284 Pa [100/110/115 VAC, 60 Hz]  

Noise Level

N/A 60 dB (A) [100 VAC, 50 Hz]
63 dB (A) [100 VAC, 60 Hz]
64 dB (A) [110/115 VAC, 60 Hz]

Components

N/A MB1040-B (Fan Unit)
PAS4B (Mounting Bracket)
FLB10 (Filter)
M5 x 20 mm (0.79 in.) (Mounting Screws)

Fan Kit

N/A Fan, Filter, Mounting Bracket, Mounting Screws

RoHS Compliant

N/A Yes

Safety Standards

N/A UL CSA EN CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

N/A 81ºF (45ºC) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

N/A Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

N/A Operating temperature, open: 248ºF ± 9ºF (120ºC ± 5ºC), close: 170.6ºF ± 27ºF (77ºC ±15ºC) Built-in thermal protector (automatic reset type)

Ambient Temperature Range

N/A 14ºF ~ 122ºF (-10ºC ~ 50ºC)

Ambient Humidity

N/A 85% or less (noncondensing)


 


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.