COMPANY HEADER
Request Information
Centrifugal fans / blowers maximize static pressure to provide concentrated airflow in one defined direction. These blowers can be used in a fixed position or mounted on moving parts, and are optimal for local cooling and airflow through ducts.

Unit of Measure
Lead Time1 N/A {Contact your local sales office for more information.}

Fan Type

N/A Centrifugal Fan / Blower

Impeller Diameter

N/A 6.30 in.160 mm

Power Supply

N/A Single-Phase 200/220/230 VAC

Current (A)

N/A 1.3 [200/230 VAC, 50 Hz]
1.8 [200/220/230 VAC, 60 Hz]

Speed (r/min)

N/A 2700 [200 VAC, 50 Hz]
2750 [230 VAC, 50 Hz]
3000 [200 VAC, 60 Hz]
3150 [220/230 VAC, 60 Hz]

Max. Air Flow

N/A 272 CFM [200 VAC, 50 Hz]
282 CFM [230 VAC, 50 Hz]
297 CFM [200 VAC, 60 Hz]
307 CFM [220 VAC, 60 Hz]
314 CFM [230 VAC, 60 Hz]  
7.7 m3/min [200 VAC, 50 Hz]
8.0 m3/min [230 VAC, 50 Hz]
8.4 m3/min [200 VAC, 60 Hz]
8.7 m3/min [220 VAC, 60 Hz]
8.9 m3/min [230 VAC, 60 Hz]  

Max. Static Pressure

N/A 1.96 inH2O [200/230 VAC, 50 Hz]
2.75 inH2O [200/220/230 VAC, 60 Hz]  
490 Pa [200/230 VAC, 50 Hz]
686 Pa [200/220/230 VAC, 60 Hz]  

Noise Level

N/A 75 dB (A) [200/230 VAC, 50 Hz]
76 dB (A) [200 VAC, 60 Hz]
77 dB (A) [220/230 VAC, 60 Hz]

Fan Kit

N/A Fan Only

RoHS Compliant

N/A Yes

Safety Standards

N/A UL CSA

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

N/A 81ºF (45ºC) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

N/A Class B (266ºF [130ºC])

Overheat Protection

N/A Built-in thermal protector (automatic reset type)
Operating temperature, open: 266ºF±9ºF (130ºC±5ºC), close: 181.4ºF±27ºF (83ºC±15ºC)

Ambient Temperature Range

N/A 14ºF ~ 122ºF (-10ºC ~ 50ºC)

Ambient Humidity

N/A 85% or less (noncondensing)


 


 


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.