Centrifugal fans / blowers maximize static pressure to provide concentrated airflow in one defined direction. These blowers can be used in a fixed position or mounted on moving parts, and are optimal for local cooling and airflow through ducts.

Unit of Measure
Lead Time1

Fan Type

Centrifugal Blower

Impeller Diameter

3.94 in.100 mm

Power Supply

Single-Phase 110/115 VAC

Current (A)

0.45 [110 VAC, 60 Hz]
0.43 [115 VAC, 60 Hz]

Speed (r/min)

3200 [110/115 VAC, 60 Hz]

Max. Air Flow

88.29 CFM [110/115 VAC, 60 Hz]  2.5 m3/min [110/115 VAC, 60 Hz]  

Max. Static Pressure

1.29 inH2O [110/115 VAC, 60 Hz]  320 Pa [110/115 VAC, 60 Hz]  

Noise Level

62 dB (A) [110/115 VAC, 60 Hz]

Safety Standards

UL CSA CE

CE Marking

Low Voltage Directives

Insulation Resistance

100 MΩ or more when 500 VDC megger is applied between the windings and the case after continuour operation under normal ambient temperature and humidity.

Dielectric Strength

Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the case for 1 minute after continous operation under normal ambient temperature and humidity.

Temperature Rise

81ºF (45ºC) or less is measured by the thermometer method when the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

UL/CSA Standards, EN Standards: 130 (B)

Overheat Protection

Built-in thermal protector (Automatic return type)
Release 266ºF±9ºF (130ºC±5ºC), Reset: 185ºF±68ºF (85ºC±20ºC)

Ambient Temperature Range

14ºF ~ 122ºF (-10ºC ~ 50ºC)

Ambient Humidity

85% or less (noncondensing)
  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.

 

©2025 - ORIENTAL MOTOR USA CORP. - All Rights Reserved