COMPANY HEADER
Request Information
Cross Flow fans employ a specifically designed blade to create parallel air movement that reaches even distant objects in a wide, uniform pattern. These fans provide right-angle airflow and rectangular shape, allowing for installation in corners and space savings in applications such as circuit board cooling and air curtains.
  • Left-mounted motor
Unit of Measure
Lead Time1 N/A {Contact your local sales office for more information.}

Product Line

N/A ORIX®

Fan Type

N/A Cross Flow

Frame Size

N/A 3.54 in90 mm

Impeller Length

N/A 5.91 in.150 mm

Motor Mount

N/A Left

Power Supply

N/A Single-Phase 200/220/230 VAC

Frequency

N/A 50 Hz60 Hz

Current

N/A 0.2 A [200/230 VAC, 50 Hz] 0.25 A [200/220/230 VAC, 60 Hz]

Speed (r/min)

N/A 2650 [200 VAC, 50 Hz]
2800 [230 VAC, 50 Hz]
2950 [200 VAC, 60 Hz]
3200 [220 VAC, 60 Hz]
3250 [230 VAC, 60 Hz]

Max. Air Flow

N/A 120 CFM [200 VAC, 50 Hz]
127 CFM [230 VAC, 50 Hz]
131 CFM [200 VAC, 60 Hz]
141 CFM [220 VAC, 60 Hz]
145 CFM [230 VAC, 60 Hz]  
3.4 m3/min [200 VAC, 50 Hz]
3.6 m3/min [230 VAC, 50 Hz]
3.7 m3/min [200 VAC, 60 Hz]
4.0 m3/min [220 VAC, 60 Hz]
4.1 m3/min [230 VAC, 60 Hz]  

Max. Static Pressure

N/A 0.353 inH2O [200 VAC, 50 Hz]
0.369 inH2O [230 VAC, 50 Hz]
0.509 inH2O [200 VAC, 60 Hz]
0.529 inH2O [220/230 VAC, 60 Hz]  
88 Pa [200 VAC, 50 Hz]
92 Pa [230 VAC, 50 Hz]
127 Pa [200 VAC, 60 Hz]
132 Pa [220/230 VAC, 60 Hz]  

Noise Level

N/A 60 dB (A) [200 VAC, 50 Hz]
61 dB (A) [230 VAC, 50 Hz]
63 dB (A) [200 VAC, 60 Hz]
64 dB (A) [220/230VAC, 60 Hz]

RoHS Compliant

N/A Yes

Safety Standards

N/A UL CSA EN CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

N/A 81ºF (45ºC) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

N/A Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

N/A Built-in thermal protector (automatic reset type)
Operating temperature, open: 248ºF±9ºF (120ºC±5ºC), close: 170.6ºF±27ºF (77ºC±15ºC)

Ambient Temperature Range

N/A 14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

N/A 85% or less (noncondensing)


 


 


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.