| Lead Time1 | N/A {Contact your local sales office for more information.} |
Product Line |
N/A ORIX® |
Fan Type |
N/A Cross Flow |
Frame Size |
N/A 3.54 in90 mm |
Impeller Length |
N/A 11.81 in.300 mm |
Motor Mount |
N/A Right |
Power Supply |
N/A Single-Phase 100/110/115 VAC |
Frequency |
N/A 50 Hz60 Hz |
Current |
N/A 0.4 A [100 VAC, 50 Hz] 0.5 A [100/110/115 VAC, 60 Hz] |
Speed (r/min) |
N/A
2500 [100 VAC, 50 Hz] 2700 [100 VAC, 60 Hz] 2950 [110 VAC, 60 Hz] 3000 [115 VAC, 60 Hz] |
Max. Air Flow |
N/A
212 CFM [100 VAC, 50 Hz] 219 CFM [100 VAC, 60 Hz] 233 CFM [110 VAC, 60 Hz] 240 CFM [115 VAC, 60 Hz] 6.0 m3/min [100 VAC, 50 Hz] 6.2 m3/min [100 VAC, 60 Hz] 6.6 m3/min [110 VAC, 60 Hz] 6.8 m3/min [115 VAC, 60 Hz] |
Max. Static Pressure |
N/A
0.297 inH2O [100 VAC, 50 Hz] 0.413 inH2O [100 VAC, 60 Hz] 0.425 inH2O [110/115 VAC, 60 Hz] 74 Pa [100 VAC, 50 Hz] 103 Pa [100 VAC, 60 Hz] 106 Pa [110/115 VAC, 60 Hz] |
Noise Level |
N/A
58 dB (A) [100 VAC, 50 Hz] 60 dB (A) [100 VAC, 60 Hz] 62 dB (A) [110 VAC, 60 Hz] 63 dB (A) [115 VAC, 60 Hz] |
RoHS Compliant |
N/A Yes |
Safety Standards |
N/A UL CSA EN CE |
CE Marking |
N/A Low Voltage Directives |
California Proposition 65 |
N/A
⚠ CA WARNING Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov See "?" or copy/paste www.P65Warnings.ca.gov in your browser. |
Insulation Resistance |
N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity. |
Dielectric Strength |
N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity. |
Temperature Rise |
N/A 81ºF (45ºC) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity. |
Insulation Class |
N/A Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards. |
Overheat Protection |
N/A
Built-in thermal protector (automatic reset type) Operating temperature, open: 248ºF±9ºF (120ºC±5ºC), close: 170.6ºF±27ºF (77ºC±15ºC) |
Ambient Temperature Range |
N/A 14ºF ~ 140ºF (-10ºC ~ 60ºC) |
Ambient Humidity |