COMPANY HEADER
Request Information
The MRE Series long-life fans have an expected life of 100,000 hours.
  • High efficiency
  • Low noise
  • Alarm type
  • Works with common Inverters to allow for variable speed
  • Fan kit includes, long-life axial flow fan, connection cables, finger guard and mounting screws.

Fan Kit

Unit of Measure
Lead Time1 N/A {Contact your local sales office for more information.}

Fan Type

N/A Axial Flow

Frame Size

N/A 6.30 in160 mm

Thickness

N/A 2.44 in.62 mm

Power Supply

N/A Three-Phase 220/230 VAC

Frequency

N/A 50 Hz60 Hz

Current

N/A 0.15 A [200 VAC, 50 Hz / 230 VAC, 60 Hz]
0.13 A [200 VAC, 60 Hz]
0.14 A [220 VAC, 60 Hz]

Function

N/A Low Speed Alarm - Contact: ON

Connection Type

N/A Terminal Box

Speed (r/min)

N/A 2800 [200 VAC, 50 Hz]
3250 [200 VAC, 60 Hz]
3300 [220/230 VAC, 60 Hz]

Max. Air Flow

N/A 219 CFM [200 VAC, 50 Hz]
258 CFM [200/220/230 VAC, 60 Hz]  
6.2 m3/min [200 VAC, 50 Hz]
7.3 m3/min [200/220/230 VAC, 60 Hz]  

Max. Static Pressure

N/A 0.509 inH2O [200 VAC, 50 Hz]
0.63 inH2O [200/220/230 VAC, 60 Hz]  
127 Pa [200 VAC, 50 Hz]
157 Pa [200/220/230 VAC, 60 Hz]  

Noise Level

N/A 49 dB (A) [100 VAC, 50 Hz]
52 dB (A) [100 VAC, 60 Hz]
53 dB (A) [110/115 VAC, 60 Hz]

Components

N/A MRE16-TBH (Fan Unit)
FG16D (Finger Guard)
Connection Cable
M5 x 20mm (Mounting Screws)

Fan Kit

N/A Fan, Finger Guard, Mounting Screws

RoHS Compliant

N/A These products do not contain substances that exceed the regulation values in the RoHS Directive.

Safety Standards

N/A UL CSA EN CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Alarm Type

N/A Contact

Alarm Activation Speed

N/A 1800 ± 300 r/min

Output Mode

N/A Relay output

Output Condition

N/A Normal operation: Contact ON
Alarm output: Contact OFF

Maximum Rating

N/A Contact capacity Resistive load max. 10 VA (max. 100 V/max. 0.5 A)
Minimum load 5 VDC 1 mA (Design your circuit to operate at 0.5 mA max.)

Delay Function

N/A None (External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be 10 sec. min.)

Circuit Connection

N/A
Circuit Connection


 

 


 


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.