COMPANY HEADER
Request Information
Axial fans use a propeller to create a flow of air the direction of the axis of rotation. Because they create a large airflow, axial fans are optimal for a wide variety of cooling and other airflow needs.
  • High efficiency
  • Low noise
  • Alarm type
Unit of Measure
Lead Time1 N/A {Contact your local sales office for more information.}

Product Line

N/A ORIX®

Fan Type

N/A Axial Fan

Frame Size

N/A 6.30 in160 mm

Power Supply

N/A Single-Phase 230 VAC

Frequency

N/A 50 Hz60 Hz

Current

N/A 0.24 A [200 VAC, 50/60 Hz] 0.25 A [230 VAC, 60 Hz]

Function

N/A Low Speed Alarm - Contact: OFF

Connection Type

N/A Terminal Box

Speed (r/min)

N/A 2800 [200 VAC, 50 Hz]
3250 [200 VAC, 60 Hz]
3300 [230 VAC, 60 Hz]

Max. Air Flow

N/A 219 CFM [200 VAC, 50 Hz]
258 CFM [200/230 VAC, 60 Hz]  
6.2 m3/min [200 VAC, 50 Hz]
7.3 m3/min [200/230 VAC, 60 Hz]  

Max. Static Pressure

N/A 0.509 inH2O [200 VAC, 50 Hz]
0.63 inH2O [200/230 VAC, 60 Hz]  
127 Pa [200 VAC, 50 Hz]
157 Pa [200/230 VAC, 60 Hz]  

Noise Level

N/A 49 dB (A) [200 VAC, 50 Hz]
52 dB (A) [200 VAC, 60 Hz]
53 dB (A) [230 VAC, 60 Hz]

Fan Kit

N/A Fan Only

RoHS Compliant

N/A Yes

Safety Standards

N/A cUL EN CE

CE Marking

N/A Low Voltage Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

N/A Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

N/A 54ºF (30ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

N/A Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

N/A Built-in thermal protector (automatic reset type)
Operating temperature, open: 248ºF±9ºF (120ºC±5ºC), close: 170.6ºF±27ºF (77ºC±15ºC)

Ambient Temperature Range

N/A 14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

N/A 85% or less (noncondensing)

Alarm Type

N/A Contact

Alarm Activation Speed

N/A 1800 ± 300 r/min

Output Mode

N/A Relay output

Output Condition

N/A Normal operation: Contact OFF
Alarm output: Contact ON

Maximum Rating

N/A Contact capacity
Resistive load: max. 10 VA (max. 100 V/max. 0.5 A)

Delay Function

N/A Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 1 second.

Circuit Connection

N/A
Circuit Connection


 


 


 


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.