COMPANY HEADER
Request Information
The PKP Series 5-phase stepper motor offers superior performance, high torque while providing low vibration and low noise. Basic step angle is 0.72º (500 steps per rev).
  • Motor cable required for connection (see Accessories)
  • DC Driver input type motor only
Unit of Measure
Lead Time1 N/A {Contact your local sales office for more information.}

Frame Size

N/A 2.36 in60 mm

Output Shaft

N/A Metric

Output Shaft Diameter

N/A 10 mm

Motor Length

N/A 3.86 in.98 mm

Basic Step Angle

N/A 0.72º

Step Angle

N/A 0.2 °

Holding Torque

N/A 254.4 oz-in1.8 N·m

Current per Phase

N/A 2.8 A/phase

Type

N/A Geared

Shaft/Gear Type

N/A Spur Gear (Offset Shaft)

Gear Type

N/A Spur Gear, Low Backlash (up to 45 arc min), Offset Shaft

Gear Ratio (X:1)

N/A 3.6 :1

Backlash

N/A 35 arcmin (0.59°)

Motor Connection Type

N/A Flat Connector

Shaft

N/A Double

Connection Type

N/A New Pentagon (Bipolar)

Lead Wires

N/A 5

Rotor Inertia

N/A 1.48 oz-in²270x10-7 kg·m²

Shaft Runout

N/A 0.05 mm (0.002 in.) T.I.R.

Concentricity

N/A 0.075 mm (0.003 in.) T.I.R.

Perpendicularity

N/A 0.075 mm (0.003 in.) T.I.R.

Radial Play

N/A 0.025 mm (0.001 in.) maximum of 5 N (1.12 lb.)

Radial Load

N/A 0 in. from Shaft End = 27 lb0.2 in. from Shaft End = 30 lb0.39 in. from Shaft End = 33.7 lb0.59 in. from Shaft End = 37 lb0.79 in. from Shaft End = lb0 mm from Shaft End = 120 N5 mm from Shaft End = 135 N10 mm from Shaft End = 150 N15 mm from Shaft End = 165 N20 mm from Shaft End = N

Axial Play

N/A 0.075 mm (0.003 in.) maximum of 10 N (2.2 lb.)

Axial Load

N/A 9 lb40 N

RoHS Compliant

N/A These products do not contain substances that exceed the regulation values in the RoHS Directive.

Safety Standards

N/A CE

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Insulation Resistance

N/A 100 MΩ or more when 500 VDC megger is applied between the windings and the case under normal ambient temperature and humidity.

Dielectric Strength

N/A No abnormalities are observed, even when applying voltage between the windings and the case for 1 minute under normal ambient temperature and humidity with the following conditions. 1 kVAC 50/60 Hz

Temperature Rise

N/A Winding temperature rise 144ºF (80ºC) max.

Ambient Temperature Range

N/A 14 ~ 122ºF (-10 ~ 50ºC) (non-freezing)

Ambient Humidity

N/A 85% or less (Non-condensing)


 


 


 


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.