COMPANY HEADER
Request Information
Each component can be purchased individually. The package item number is scheduled to be discontinued. Please contact our technical support team for a replacement.
Unit of Measure

Return Policy

N/A This product cannot be cancelled or returned once the order has been processed.

Basic Step Angle

N/A 0.72º

Frame Size

N/A 1.65 in42 mm

Motor Length

N/A 1.34 in.34 mm

Speed-Torque Characteristics

N/A
 

Holding Torque

N/A 19.80 oz-in0.14 N·m

Type

N/A Standard

Shaft/Gear Type

N/A Round Shaft (No Gearhead)

Encoder

N/A Not Equipped

Shaft

N/A Single

Electromagnetic Brake

N/A Not Equipped

Power Supply

N/A Single-Phase 100-120 VAC

Current

N/A 2.1 A

Rotor Inertia

N/A 0.16 oz-in²30x10-7 kg·m²

Radial Load

N/A 0 in. from Shaft End = 7.8 lb0.2 in. from Shaft End = 9.9 lb0.39 in. from Shaft End = 13 lb0.59 in. from Shaft End = 19.1 lb0 mm from Shaft End = 35 N5 mm from Shaft End = 44 N10 mm from Shaft End = 58 N15 mm from Shaft End = 85 N

Axial Load

N/A 3.3 lb15 N

RoHS Compliant

N/A Yes

Safety Standards

N/A UL CE

CE Marking

N/A Low Voltage Directives EMC Directives

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Components

N/A RKSD503-AD [Driver] PKE543AC [Motor]

Degree of Protection

N/A [Motor] IP20
[Driver] IP10

Number of Positioning Data Sets

N/A 64

Positioning Operation

N/A One-shot operation, Linked operation, Linked operation 2, Sequential mode, Direct mode

Other Operation

N/A Continuous Operation, JOG Operation, Return-to-Home Operation, Test Operation

Protocol

N/A Modbus Protocol (Modbus RTU mode)

Electrical Characteristics

N/A EIA-485 compliance
Twisted-pair wire (TIA/EIA-568B CAT5e or greater recommended) is used up to a total extension length of 50 m.

Transmission/Reception Mode

N/A Half-duplex communication

Baud Rate

N/A 9600 bps/19200 bps/57600 bps/115200 bps

Physical Layer

N/A Asynchronous mode (data: 8-bit, stop bit: 1-bit/2-bit, parity: none/odd/even)

Connection Type

N/A Up to 31 units can be connected to one programmable controller (master equipment).