The BLH Series Driver has been updated to now include three driver types, an RS-485 Communication type, a Digital type driver or the traditional Analog type. The BLH Series is a 24 VDC, brushless DC motor and driver package offering a wide speed range of 100 to 3000 r/min (80 to 3000 r/min with digital driver type and RS-485 communications type). RS-485 and Digital type driver are used with our MEXE02 support software (available for free download) for improved functions including torque sensing and predictive maintenance monitoring. A wide range of motor options are available to meet your application needs.
Items |
BLHM230KC-5 / BLH2D30-K 30 W (1/25 HP) Brushless DC Motor Speed Control System (5:1 Gear Ratio) (24 VDC) Web Price Request Quote
|
BLHM230KC-10 / BLH2D30-K 30 W (1/25 HP) Brushless DC Motor Speed Control System (10:1 Gear Ratio) (24 VDC) Web Price Request Quote
|
BLHM230KC-15 / BLH2D30-K 30 W (1/25 HP) Brushless DC Motor Speed Control System (15:1 Gear Ratio) (24 VDC) Web Price Request Quote
|
BLHM230KC-20 / BLH2D30-K 30 W (1/25 HP) Brushless DC Motor Speed Control System (20:1 Gear Ratio) (24 VDC) Web Price Request Quote
|
BLHM230KC-30 / BLH2D30-K 30 W (1/25 HP) Brushless DC Motor Speed Control System (30:1 Gear Ratio) (24 VDC) Web Price Request Quote
|
|||||
Motor Frame Size |
- 2.36 in.60 mm | |||||||||
Output Power | - 30 W (1/25 HP) | |||||||||
Power Supply | - 24 VDC | |||||||||
Driver Type | - Analog | |||||||||
Type | - Cable | |||||||||
Shaft/Gear Type | - Parallel Shaft Gearhead | |||||||||
Gear Ratio (X:1) | - 5 :1 | - 10 :1 | - 15 :1 | - 20 :1 | - 30 :1 | |||||
Output Shaft Diameter | - 10 mm | |||||||||
Degree of Protection (Motor) | - IP65 | |||||||||
Rated Torque | - 4.6 lb-in0.52 N·m | - 8.8 lb-in1 N·m | - 14.1 lb-in1.6 N·m | - 18.5 lb-in2.1 N·m | - 26 lb-in3 N·m | |||||
Variable Speed Range (r/min) | - 20 ~ 600 | - 10 ~ 300 | - 6.7 ~ 200 | - 5 ~ 150 | - 3.3 ~ 100 | |||||
Permissible Load Inertia | - 66 oz-in²*When instantaneous stop or instantaneous bi-directional operation is performed = 8.5 oz-in²12 x 10-4 kg·m²*When instantaneous stop or instantaneous bi-directional operation is performed = 1.55 x 10-4 kg·m² | - 270 oz-in²*When instantaneous stop or instantaneous bi-directional operation is performed = 34 oz-in²50 x 10-4 kg·m²*When instantaneous stop or instantaneous bi-directional operation is performed = 6.2 x 10-4 kg·m² | - 600 oz-in²*When instantaneous stop or instantaneous bi-directional operation is performed = 77 oz-in²110 x 10-4 kg·m²*When instantaneous stop or instantaneous bi-directional operation is performed = 14 x 10-4 kg·m² | - 1090 oz-in²*When instantaneous stop or instantaneous bi-directional operation is performed = 136 oz-in²200 x 10-4 kg·m²*When instantaneous stop or instantaneous bi-directional operation is performed = 24.8 x 10-4 kg·m² | - 2000 oz-in²*When instantaneous stop or instantaneous bi-directional operation is performed = 310 oz-in²370 x 10-4 kg·m²*When instantaneous stop or instantaneous bi-directional operation is performed = 55.8 x 10-4 kg·m² | |||||
Permissible Overhung Load | - 0.39 in. from Shaft End = 22 lb0.79 in. from Shaft End = 33 lb10 mm from Shaft End = 100 N20 mm from Shaft End = 150 N | - 0.39 in. from Shaft End = 33 lb0.79 in. from Shaft End = 45 lb10 mm from Shaft End = 150 N20 mm from Shaft End = 200 N | - 0.39 in. from Shaft End = 33 lb0.79 in. from Shaft End = 45 lb10 mm from Shaft End = 150 N20 mm from Shaft End = 200 N | - 0.39 in. from Shaft End = 33 lb0.79 in. from Shaft End = 45 lb10 mm from Shaft End = 150 N20 mm from Shaft End = 200 N | - 0.39 in. from Shaft End = 45 lb0.79 in. from Shaft End = 67 lb10 mm from Shaft End = 200 N20 mm from Shaft End = 300 N | |||||
Permissible Thrust Load | - 9 lb40 N | |||||||||
Permissible Thrust Load | - | |||||||||
Electromagnetic Brake | - Not Equipped | |||||||||
Speed Control Method (Select one of the following) | - Internal potentiometer External DC voltage External potentiometer (20kΩ, 1/4W) | |||||||||
Number of Speed Settings | - 2-speed operation is possible | |||||||||
Multi-Speed Setting Method |
-
External speed potentiometer or external DC voltage: 0 to 5 VDC, 1 mA min VR1 |
|||||||||
Max. Extension Length (m) |
- 2 | |||||||||
RoHS Compliant |
- Yes | |||||||||
I/O Functions |
-
Direct Input Method: C-MOS Negative Logic Input Point: 5 Points Initial Assignment: START/STOP, RUN/BRAKE, FWD/REV, M0, ALM-RST Direct Output Method: Transistor and open-collector output Point: 2 Points Initial Assignment: SPEED-OUT, ALM-B |
|||||||||
|