Motor Type

Brushless DC Motor

Motor Frame Size

4.09 in.

Output Power

200 W (1/4 HP)

Power Supply

24 VDC

Shaft/Gear Type

Hollow Shaft Flat Gearhead

Gear Ratio (X:1)

50 :1

Output Shaft Diameter

25 mm

Rated Torque

240 lb-in

Electromagnetic Brake

Not Equipped

Variable Speed Range (r/min)

2 ~ 80

Permissible Load Inertia

51000 oz-in²*When instantaneous stop or instantaneous bi-directional operation is performed = 27000 oz-in²

Permissible Overhung Load

0.39 in. from gearhead mounting surface = 450 lb0.79 in. from gearhead mounting surface = 400 lb

Permissible Thrust Load

180 lb

Type

Cable

Speed Control Method (Select one of the following)

Internal potentiometer External DC voltage External potentiometer (20kΩ, 1/4W)

Number of Speed Settings

2 Standard / 8 with MEXE02 Softwre or OPX-2A Controller

Instantaneous Stop

Yes

Multi-Axes Control

Yes

Alarm Output

Yes

Power Input

DC

Max. Extension Length (m)

3.5

Components

BLVD20KM, Brushless DC Motor Driver (Request Quote)
BLVM620K-GFS, 200 W (1/4 HP) BLV Series Brushless DC Pinion Shaft Motor () ($267.00)
GFS6G50FR, GFS Hollow Shaft Flat Gearhead (50:1) ($352.00)

RoHS Compliant

Yes

Safety Standards

CE

CE Marking

EMC Directives

Insulation Class

[Motor] EN: Class E [120ºC (248ºF)]

Insulation Resistance (Motor)

100 MΩ or more when 500 VDC megger is applied between the windings and the frame after continuous operation under normal ambient temperature and humidity.

Insulation Resistance (Driver)

100 M Ω or more when 500 VDC megger is applied between the power supply terminal and heat radiation plate after continuous operation under normal ambient temperature and humidity.

Dielectric Strength (Motor)

Sufficient to withstand 0.5 kVAC at 50Hz applied between the windings and the frame for 1 minute after continuous operation under normal ambient temperature and humidity.

Dielectric Strength (Driver)

Sufficient to withstand 0.5 kVAC at 50Hz applied between the power supply terminal and the heat radiation plate for 1 minute after continuous operation under normal ambient temperature and humidity.

Ambient Temperature Range

0ºC ~ +40ºC (+32ºF ~ +104ºF) (nonfreezing)

Ambient Humidity

85% max. (noncondensing)

Operating Atmosphere

No corrosive gases or dust. Cannot be used in radioactive area, magnetic field, vacuum or other special environment.

Degree of Protection

[Motor] IP40 [Driver] IP20

Degree of Protection (Motor)

IP40

Communications

Communication Protocol

Modbus Protocol (Modbus RTU mode)

Electrical Characteristics

Complies with EIA-485
The maximum total length of communicatoin cable is 50 m when using twisted-pair wire (TIA/EIA-568B CAT5e or better recommended)

Transmission/Reception Mode

Half duplex

Baud Rate

625000 bps

Physical Layer

Start-stop synchronization (data: 8 bits, stop bit: 1 bit, parity: none)

Dimensions


 

 

Speed-Torque


 

System


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.