The EMR Series AC axial fans have an expected life of 60,000 hours.
  • Single-Phase 100-120 VAC
  • Available in Standard Speed and High Speed Types
  • Equipped with a brushless motor, low power consumption, low heat generation, large air flow, and high static pressure
  • Estimated life up to 60,000 hours
  • Alarm and variable speed functions available
Unit of Measure
Lead Time1 - {Contact your local sales office for more information.}

Fan Type

- Axial Flow

Frame Size

- 7.87 in200 mm

Thickness

- 3.54 in.90 mm

Power Supply

- Single-Phase 100-120 VAC

Frequency

- 50 Hz60 Hz

Current

- 0.96 A

Function

- Low Speed Alarm - Electronic

Connection Type

- Lead Wire

Speed (r/min)

- 4150

Max. Air Flow

- 710 CFM  20.1 m3/min  

Max. Static Pressure

- 1.17 inH2O  290 Pa  

Noise Level

- 68 dB (A)

RoHS Compliant

- These products do not contain substances that exceed the regulation values in the RoHS Directive.

Safety Standards

- UL CE

CE Marking

- Low Voltage Directives

California Proposition 65

- CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Dielectric Strength

- Sufficient to withstand 1.8 kV at 50 Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

- 54ºF (30ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Thermal Class

- EN Standards: 120 (E)

Ambient Temperature Range

- -4ºF ~ 131ºF (-20ºC ~ 55ºC)

Ambient Humidity

- 85% or less (noncondensing)

Alarm Type

- Electronic

Alarm Activation Speed

- When the fan speed is reduced by 40% or more due to adhesion of foreign objects or a drop in the power supply voltage.

Output Mode

- PhotoMOS Relays Output

Output Condition

- Normal operation: Contact ON; Alarm output: Contact OFF

Maximum Rating

- Maximum applied voltage: 40 VDC or less; Maximum inflow current: 500 mA or less

Delay Function

- External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be 10 sec. min.

Circuit Connection

-
Circuit Connection


 

 


 