Items |
FRN0010C2S-7U Compact Inverter (VFD) for 2 HP Motors (Single-Phase 230 VAC) Web Price $289.85
|
FRN0010C2S-2U Compact Inverter (VFD) for 2 HP Motors (Three-Phase 230 VAC) Web Price $244.80
|
FRN0005C2S-4U Compact Inverter (VFD) for 2 HP Motors (Three-Phase 460 VAC) Web Price $344.25
|
|||
Nominal Motor HP | - 2 HP | |||||
Power Supply | - Single-Phase 200 to 240 V, 50/60 Hz | - Three-Phase 200 to 240 V, 50/60 Hz | - Three-Phase 380 to 480V, 50/60 Hz | |||
Voltage / Frequency Variations (Input) | - Voltage: +10 to -10%, Frequency: +5 to -5% | - Voltage: +10% to -15% (Voltage unbalance: 2% or less), Frequency: +5 to -5% | - Voltage: +10% to -15% (Voltage unbalance: 2% or less), Frequency: +5 to -5% | |||
Rated Current (Input) |
-
11.6 A (with DCR) 16.4 A (without DCR) |
-
5.7 A (with DCR) 9.5 A (without DCR) |
-
3.0 A (with DCR) 5.9 A (without DCR) |
|||
Required Power Supply Capacity (Input) | - 2.4 kVA | - 2.0 kVA | - 2.0 kVA | |||
Rated Capacity (Output) | - 3.5 kVA | - 3.5 kVA | - 3.2 kVA | |||
Rated Voltage (Output) | - Three-Phase 200 to 240V (With AVR) | - Three-Phase 200 to 240V (With AVR) | - Three-Phase 390 to 480V (With AVR) | |||
Rated Current (Output) |
- 9.2 A (7.0 A) | - 9.2 A (7.0 A) | - 4.3 A (3.7 A) | |||
Overload Capability (Output) |
-
150% of rated current for 1 min 150% of rated current for 1 min or (200% of rated current for 0.5s (For rated current in parenthesis) |
|||||
Rated Frequency (Output) | - 50, 60 Hz | |||||
Maximum Output Frequency |
-
Adjustable up to 400 Hz. However, when using with Oriental Motor or Brother Gearmotors, limit the motor output speed to 120 Hz (3,600 r/min). |
|||||
Torque % (Braking) | - 50 | |||||
DC Injection Braking (Brake) | - Starting Frequency: 0.0 to 60.0 Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% | |||||
Braking Transistor (Brake) | - Built-in | |||||
Motor Control Method |
-
Induction Motor: V/f, Dynamic Torque Vector, Slip Comp, Auto-Torque Boost, Automatic Energy Savings Synchronous Motor (PMAC): Sensorless Magnetic Positioning [speed control range: 10% of base frequency and up] |
|||||
Protocol | - Modbus RTU Mode / RS-485 Port | |||||
Analog Inputs |
-
0 to +10 VDC 0 to 20mA or 4 to 20 mA |
|||||
Digital Inputs | - Qty 5: Programmable | |||||
Input Power Supply | - 24 VDC 50 mA Max | |||||
Analog Outputs | - Qty 1: 0 to +10VDC, User Selectable Proportional Analog Signal Functionality | |||||
Digital Outputs |
-
Qty 1: Form C (1N.O. & 1N.C.) Dry Contacts Rated 0.3A at 230V Max, User Selectable Functionality Qty 1: Transistor Output Rated 50mA at 27Vdc Max, User Selectable Functionality |
|||||
Applicable Safety Standards | - UL508C, EN 61800-5-1:2007 | |||||
Enclosure | - IP20 (IEC 60529:1989) / UL open type (UL50) | |||||
Cooling Method | - Fan Cooling | |||||
Ambient Temperature |
-
+14 to +122ºF (-10 to +50ºC) - UL Open Type +14 to +104ºF (-10 to +40ºC) - UL Type 1 |
|||||
Storage Temperature | - -13 to +158ºF (-25 to +70ºC) | |||||
Humidity | - 5% to 95% With No Condensation | |||||
Altitude | - 0 to 3,300 ft. (1,000 m) Without Derating, Derate Output Current for Higher Altitudes per User's Manual | |||||
|