A power controller developed for Oriental Motor's torque motors that allows for easy adjustment of torque. A perfect choice for winding applications, push-motion mechanisms and other situations where torque must be adjusted
  • Torque can be set using one of three methods; internal potentiometer, external potentiometer or external DC voltage
  • Change between two levels by switching between the internal potentiometer and an external potentiometer/voltage
  • Alarm output function
  • Instantaneous bi-directional operation by CW/CCW signal switching
  • Switching of signal input logic between sink and source

Power Controller

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Accessories

Unit of Measure
Available to Ship1 - {Contact your local sales office for more information.}

Power Supply

- Single-Phase 100/110/115 VAC ±10% 50/60 Hz Single-Phase 200/220/230 VAC ±10% 50/60 Hz

Power Source for Control

- 24 VDC ±10%, 100 mA or more

Input Signals

- Photocoupler input, Input resistance 4.7 kΩ
CW input, CCW input, INT/EXT switch input, Alarm reset input

Output Signals

- Open collector output: 4.5 ~ 26.4 VDC or less, 40 mA or less.
Alarm output

RoHS Compliant

- Yes

Safety Standards

- UL EN CE

CE Marking

- Low Voltage Directives EMC Directives

Insulation Resistance

- 100 MΩ or more when 500 VDC megger is applied between the main circuit terminals and the control circuit terminals after continuous operation under normal ambient temperature and humidity.

Dielectric Strength

- Sufficient to withstand 3.0 kVAC at 50 Hz or 60 Hz applied between the main circuit terminals and the control circuit terminals for 1 minute under normal ambient temperature and humidity.

Ambient Temperature

- 0 ~ 50ºC (32 ~ 122ºF) (non-freezing)

Ambient Humidity

- 85% or less (Non-Condensing)

Degree of Protection

- IP20

Torque Setting Method

- Select one of the following methods:
  • Set using internal torque potentiometer (TORQUE)
  • Set using the external torque potentiometer: PAVR-20KZ (20 kΩ, 1/4 W)
  • Set using external DC voltage: 0 to 5 VDC or 0 to 10 VDC, 1 mA or more. Torque can be adjusted using the fine-tuning potentiometer (ADJUST)

Protective Function

- When any of the following is activated, the alarm signal will be output, the alarm LED will blink and the motor will stop.
  • The built-in thermal protector of the motor has actuated (become open)
  • Improper motor cable connection or wire breakage

Motor Cable Length

- The distance between motor and power controller can be extended up to 20 m


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.

 