ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)
Motor Type |
- Hollow Rotary Actuator |
Type |
- Standard |
Frame Size (in. sq.) |
- 2.36 |
Power Supply |
- 24 VDC |
Current |
- 1.0 A |
Shaft |
- Single |
Permissible Torque (lb-in) |
- 7.9 |
Maximum Holding Torque (lb-in) |
- 3.9 |
Inertial Moment (oz-in2) |
- 24 |
Permissible Speed (r/min) |
- 200 |
Resolution |
- 18000 P/R (Resolution Setting: 0.02º/pulse [1000] [X1]) 180000 P/R (Resolution Setting: 0.002º/pulse [1000] [X10]) 9000 P/R (Resolution Setting: 0.04º/pulse [500] [X1]) 90000 P/R (Resolution Setting: 0.004º/pulse [500] [X10]) |
Repetitive Positioning Accuracy (arc sec) |
- ±15 (±0.004º) |
Lost Motion (min) |
- 2 (0.033º) |
Angle Transfer Error (min) |
- 4 (0.067º) |
Permissible Thrust Load (lb) |
- 22 |
Permissible Moment Load (lb-in) |
- 17.7 |
Parallelism of Output Table (in.) |
- 0.002 |
Components |
- ASD10A-K (Driver) DGM60-ASAK (Actuator) |
RoHS Compliant |
- Yes |
Safety Standards |
- UL CSA CE |
CE Marking |
- EMC Directives |
Insulation Class |
- [Motor] Class B (266°F [130°C]), Recognized as Class A (221°F [105°C]) by UL and CSA standards. |
Insulation Resistance |
- [Motor] 100 M O minimum when measured by a 500 VDC megger between the Frame - Motor and Sensor Windings. [Driver] 100 M O when measured by a 500 VDC megger between the Heat Sink - Power Supply Terminal. |
Dielectric Strength (Motor) |
- Sufficient to withstand the following for 1 minute: Frame - Motor and Sensor Windings 0.5 kV 50 Hz or 60 Hz |
Dielectric Strength (Driver) |
- Sufficient to withstand the following for 1 minute: Heat sink - Power supply input terminal 0.5 kV 50 Hz or 60 Hz |
Ambient Temperature Range |
- [Motor] 32°F ~ 122°F (0°C ~ 50°C) (nonfreezing), 32°F ~ 104°F (0°C ~ 40°C) when home-sensor set is attached. [Driver] 32°F ~ 104°F (0°C ~ 40°C) (nonfreezing). |
Ambient Humidity |
- 85% or less (noncondensing) |
Degree of Protection |
- [Driver] IP00 [Motor] IP40 (IP20 for motor connector) |
List Price |
-
$1,406.00 |