Centrifugal fans / blowers maximize static pressure to provide concentrated airflow in one defined direction. These blowers can be used in a fixed position or mounted on moving parts, and are optimal for local cooling and airflow through ducts.
  • Fan kit features centrifugal blower, mounting bracket, filter and mounting screws in a single package.

Fan Kits

Unit of Measure

Specifications

Lead Time1 - {Contact your local sales office for more information.}

Fan Type

- Centrifugal Blower

Impeller Diameter

- 4.72 in.

Power Supply

- Single-Phase 200/220/230 VAC

Current (A)

- 0.6 [200/230 VAC, 50 Hz]
0.8 [200/220/230 VAC, 60 Hz]

Speed (r/min)

- 2850 [200 VAC, 50 Hz]
2900 [230 VAC, 50 Hz]
3200 [200 VAC, 60 Hz]
3300 [220/230 VAC, 60 Hz]

Max. Air Flow

- 155 CFM [200 VAC, 50 Hz]
159 CFM [230 VAC, 50 Hz]
173 CFM [200 VAC, 60 Hz]
180 CFM [220 VAC, 60 Hz]
184 CFM [230 VAC, 60 Hz]  

Max. Static Pressure

- 1.26 inH2O [200/230 VAC, 50 Hz]
1.81 inH2O [200/220/230 VAC, 60 Hz]  

Noise Level

- 67 dB (A) [200/230 VAC, 50 Hz]
69 dB (A) [200 VAC, 60 Hz]
71 dB (A) [220/230 VAC, 60 Hz]

Components

- MB1255-D (Fan Unit)
PAS6A (Mounting Bracket)
FLB12 (Filter)
M5 x 20 mm (0.79 in.) (Mounting Screws)

Fan Kit

- Fan, Filter, Mounting Bracket, Mounting Screws

RoHS Compliant

- Yes

Safety Standards

- UL CSA EN CE

CE Marking

- Low Voltage Directives

Insulation Resistance

- 100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

- Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

- 81ºF (45ºC) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

- Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

- Operating temperature, open: 248ºF ± 9ºF (120ºC ± 5ºC), close: 170.6ºF ± 27ºF (77ºC ±15ºC) Built-in thermal protector (automatic reset type)

Ambient Temperature Range

- 14ºF ~ 122ºF (-10ºC ~ 50ºC)

Ambient Humidity

- 85% or less (noncondensing)