ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)
Insulation Resistance (Motor) |
-
100 MΩ or more when 500 VDC megger is applied between the following places: Case - Motor windings |
Dielectric Strength (Motor) |
-
Sufficient to withstand the following for 1 minute: Case - Motor windings 1.5 kVAC 50 Hz or 60 Hz |
Degree of Protection |
- IP20 |
Ambient Temperature Range |
- +14 ~ +122ºF (-10 ~ +50ºC) (non-freezing) |
Ambient Humidity |
- 85% or less (Non-Condensing) |
Operating Atmosphere |
- No corrosive gases, dust. Avoid contact with water or oil. |
Temperature Rise |
- Temperature rise of the windings is 144ºF (80ºC) or less. Measured at rated current, at standstill, five phases energized measured (by resistance change method). |
Shaft Runout |
- 0.002 in (0.05 mm) T.I.R. |
Concentricity |
- 0.003 in. (0.075 mm) T.I.R. |
Perpendicularity |
- 0.003 in. (0.075 mm) T.I.R. |
Stop Position Accuracy |
- ±5 arc minutes (±0.084º) |