This product has been discontinued, please contact your local sales office for more information.
Unit of Measure

Product Line

ORIX®

Fan Type

Axial Fan

Frame Size

7.09 in180 mm

Power Supply

Single-Phase 220/230 VAC

Frequency

50 Hz60 Hz

Current

0.6 A [200/230 VAC, 50 Hz] 0.7 A [200/230 VAC, 60 Hz]

Function

Variable Flow

Connection Type

Terminal Box

Speed (r/min)

1000 ~ 2800 [200 VAC, 50 Hz]
750 ~ 3200 [200 VAC, 60 Hz]
1350 ~ 2850 [230 VAC, 50 Hz]
1100 ~ 3350 [230 VAC, 60 Hz]

Max. Air Flow

138 ~ 388 CFM [200 VAC, 50 Hz]
98.8 ~ 424 CFM [200 VAC, 60 Hz]
177 ~ 388 CFM [230 VAC, 50 Hz]
141 ~ 452 CFM [230 VAC, 60 Hz]  
3.9 ~ 11.0 m3/min [200 VAC, 50 Hz]
2.8 ~ 12.0 m3/min [200 VAC, 60 Hz]
5.0 ~ 11.0 m3/min [230 VAC, 50 Hz]
4.0 ~ 12.8 m3/min [230 VAC, 60 Hz]  

Max. Static Pressure

0.0786 ~ 0.746 inH2O [200 VAC, 50 Hz]
0.0472 ~ 0.786 inH2O [200 VAC, 60 Hz]
0.146 ~ 0.786 inH2O [230 VAC, 50 Hz]
0.0942 ~ 1.02 inH2O [230 VAC, 60 hZ]  
19.6 ~ 186 Pa [200 VAC, 50 Hz]
11.8 ~ 196 Pa [200 VAC, 60 Hz]
36.3 ~ 196 Pa [230 VAC, 50 Hz]
23.5 ~ 255 Pa [230 VAC, 60 Hz]  

Noise Level

40 dB (A) [750 r/min]
61 dB (A) [3350 r/min]

Fan Kit

Fan Only

RoHS Compliant

Yes

Safety Standards

UL CSA EN CE

CE Marking

Low Voltage Directives

Insulation Resistance

100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

54ºF (30ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

Built-in thermal protector (automatic reset type)
Operating temperature, open: 248ºF±9ºF (120ºC±5ºC), close: 170.6ºF±27ºF (77ºC±15ºC)

Ambient Temperature Range

14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

85% or less (noncondensing)

 

©2025 - ORIENTAL MOTOR USA CORP. - All Rights Reserved