COMPANY HEADER
Request Information
The DGII Series uses a highly rigid hollow rotary table with an absolute mechanical encoder AZ series closed loop motor allowing for highly accurate positioning of larger inertia loads.
  • Large-Diameter, Hollow Output Table
  • Direct Coupling
Unit of Measure
Available to Ship1 N/A {Contact your local sales office for more information.}

Return Policy

N/A This product cannot be cancelled or returned once the order has been processed.

Frame Size

N/A 5.12 in130 mm

Shaft

N/A Single

Gear Ratio (X:1)

N/A 18 :1

Motor Location

N/A Horizontal Mount (Pedestal)

Cable Direction

N/A Left

Electromagnetic Brake

N/A Not Equipped

Output Table Supporting Bearing

N/A Cross-Roller Bearing

Permissible Torque

N/A 106 lb-in12 N·m

Inertia

N/A 147000x10-7 kg·m²800 oz-in²

Permissible Speed (r/min)

N/A 1200º/seconds (200 r/min)

Max. Holding Torque

N/A 106 lb-in12 N·m

Repetitive Positioning Accuracy (arc sec)

N/A ±30 arc sec (±0.008º)

Angular Transmission Accuracy

N/A 6 arc minute (0.1º)

Permissible Moment Load

N/A 160 N·m1416 lb-in

Runout of Output Table Surface

N/A 0.015 mm0.0006 in.

Runout of Output Table Inner (Outer) Diameter

N/A 0.015 mm0.0006 in.

Parallelism of Output Table

N/A 0.03 mm0.0012 in.

Degree of Protection

N/A Actuator: IP40 (IP20 for motor connector)

Insulation Class

N/A 130 (B) [Recognized as 105 (A) by the UL Standards]

Insulation Resistance (Actuator)

N/A 100 MΩ minimum when measured by a 500 VDC megger between the Case - Motor Windings

Dielectric Strength (Actuator)

N/A Sufficient to withstand the following for 1 minute: Case - Motor Windings 1.5 kV, 50 Hz or 60 Hz

Ambient Temperature (Actuator)

N/A 0 ~ +40ºC (+32 ~ 104ºF)(non-freezing)

Ambient Humidity

N/A 85% or less (Non-condensing)

Operating Atmosphere

N/A Use in an area without corrosive gases and dust. The product should not be exposed to water, oil or other liquids.

Safety Standards

N/A UL CE

RoHS Compliant

N/A This product does not contain substances that exceed the regulation values in the RoHS Directive

California Proposition 65

N/A CA WARNING
Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov
Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov
See "?" or copy/paste www.P65Warnings.ca.gov in your browser.

Power Supply

N/A AC Input


 


 

 

 

 


 

Product Number

N/A
 
  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.