Rated Output Power |
- 50 W (1/15 HP) |
Motor Frame Size |
- 2.36 in.60 mm |
Speed-Torque Characteristics |
-
![]() Loading zoom Graph |
Rated Torque |
- 450 oz-in3.22 N·m |
Permissible Speed Range |
- 0 ~ 120 r/min |
Max Instantaneous Torque |
- 1370 oz-in9.66 N·m |
Rotor Inertia |
- 0.095 oz-in²0.0174x10-4 kg·m² |
Gear Inertia |
- 0.24 oz-in²0.0431x10-4 kg·m² |
Permissible Load Inertia |
- 3000 oz-in²0.054 kg·m² |
Resolution (P/R) |
- 100 to 100000 (Factory setting 1000) |
Detector |
-
Absolute Encoder 1 rotation 20 bits, multiple rotations 16 bits |
Gear/Shaft Type |
- Planetary Gear (PS) |
Gear Ratio (X:1) |
- 25 :1 |
Backlash |
- 15 |
Electromagnetic Brake |
- Not Equipped |
Permissible Overhung Load |
- 0 in. from Shaft End = 74 lb0.2 in. from Shaft End = 81 lb0.39 in. from Shaft End = 90 lb0.59 in. from Shaft End = 101 lb0.79 in. from Shaft End = 117 lb0 mm from Shaft End = 330 N5 mm from Shaft End = 360 N10 mm from Shaft End = 400 N15 mm from Shaft End = 450 N20 mm from Shaft End = 520 N |
Permissible Thrust Load |
- 22 lb100 N |
Thermal Class |
- 130 (B) |
Insulation Resistance (Motor) |
-
100 MΩ min. when measured with a 500 VDC megger between the following locations: Case - Motor Windings |
Dielectric Voltage (Motor) |
-
No abnormality is judged with the following application for 1 minute: Case - Motor Windings 1.5 kVAC 50 Hz or 60 Hz |
Ambient Temperature (Motor) |
- 0 ~ +40ºC (32 ~ 104ºF) (non-freezing) |
Ambient Humidity |
- 85% max. (non-condensing) |
Operating Atmosphere |
- No corrosive gases. Must not be exposed to oil or other liquids. |
Degree of Protection |
- IP65 (excluding installation surface and connector locations.) |
Shaft Runout |
- 0.05 T.I.R. (mm) |
Concentricity |
- 0.075 T.I.R. (mm) |
Perpendicularity |
- 0.075 T.I.R. (mm) |
Safety Standards |
-
CE UL/CSA |
RoHS Compliant |