The MRE Series long-life fans have an expected life of 100,000 hours.
  • High efficiency
  • Low noise
  • Alarm type
Unit of Measure
Lead Time1 Contact your local sales office.
This Item cannot be cancelled or returned.

Fan Type

Axial Fan

Frame Size

6.30 in160 mm

Thickness

2.44 in.62 mm

Power Supply

Single-Phase 110/115 VAC

Frequency

50 Hz60 Hz

Current

0.45 A [100 VAC, 50 Hz]
0.44 A [100 VAC, 60 Hz]
0.46 A [110 VAC, 60 Hz]
0.48 A [115 VAC, 60 Hz]

Function

Low Speed Alarm - Electronic

Connection Type

Terminal Box

Speed (r/min)

2800 [100 VAC, 50 Hz]
3250 [100 VAC, 60 Hz]
3300 [110/115 VAC, 60 Hz]

Max. Air Flow

219 CFM [100 VAC, 50 Hz]
258 CFM [100/110/115 VAC, 60 Hz]  
6.2 m3/min [100 VAC, 50 Hz]
7.3 m3/min [100/110/115 VAC, 60 Hz]  

Max. Static Pressure

0.509 inH2O [100 VAC, 50 Hz]
0.63 inH2O [100/110/115 VAC, 60 Hz]  
127 Pa [100 VAC, 50 Hz]
157 Pa [100/110/115 VAC, 60 Hz]  

Noise Level

49 dB (A) [100 VAC, 50 Hz]
52 dB (A) [100 VAC, 60 Hz]
53 dB (A) [110/115 VAC, 60 Hz]

Fan Kit

Fan Only

RoHS Compliant

These products do not contain substances that exceed the regulation values in the RoHS Directive.

Safety Standards

UL CSA EN CE

CE Marking

Low Voltage Directives

Dielectric Strength

Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

54ºF (30ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Thermal Class

UL/CSA Standards: 105 (A), EN Standards: 120 (E)

Overheat Protection

Built-in thermal protector (automatic return type)
Open: 248ºF ± 9ºF (120ºC ± 5ºC), Close: 170.6ºF ± 27ºF (77ºC ± 15ºC)

Ambient Temperature Range

-4ºF ~ 140ºF (-20ºC ~ 60ºC)

Ambient Humidity

85% or less (noncondensing)
  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.

 