The Rotary Encoder is provided with the dust-resistant and water jet resistant structure (IP65), which has expanded the range of applications where it is used. Please consider adopting this product for textile and woodworking machinery, machine tools and food machinery that are exposed to water.
| Lead Time1 | - {Contact your local sales office for more information.} |
Mounting Size |
- 1.57 in40 mm |
Output Shaft Type |
- Round Shaft |
Resolution (P/R) |
- 720 |
Output Type |
- Incremental |
Output |
- Line Driver |
Output Signals |
- Phase A, Phase B, Phase Z: 3 Channels |
Output Circuit |
-
![]() |
Max. Draw Current |
- 20 mA |
Output Voltage (High) |
- 2.5 VDC min |
Output Voltage (Low) |
- 0.5 VDC max. |
Response Frequency (kHz) |
- 200 kHz max. |
Power Supply |
- 5 VDC ± 10% |
Current Consumption |
- 30 mA max. |
Angular Accuracy |
- ±0.36˚ |
Vibration |
- 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in X, Y, and Z directions |
Shock |
- 490 m/s2 11 ms X, Y, Z directions; 3 times each |
Inertia |
- 1.2×10−7 kg·m²0.00656097 oz-in² |
Permissible Radial Load |
- 6.74 lb30 N |
Permissible Axial Load |
- 4.5 lb20 N |
Max Speed (rpm) |
- 6000 r/min (Max. Response Frequency) |
Mass |
- 110 g3.88 oz |
California Proposition 65 |
-
⚠ CA WARNING Cancer risk from exposure to Nickel. See www.P65Warnings.ca.gov Risk of reproductive harm from exposure to Di-n-hexyl phthalate (DnHP). See www.P65Warnings.ca.gov Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl phthalate (DEHP). See www.P65Warnings.ca.gov See "?" or copy/paste www.P65Warnings.ca.gov in your browser. |
Ambient Temperature |
- −10 to +70 °C (+14 to 158 °F) (non-freezing) |
Ambient Humidity |
- 85 % or less (non-condensing) |
Altitude |
- Up to 1,000 m (3,300 ft.) above sea level |
Degree of Protection |
- IP65 |
Operating Atmosphere |
- No corrosive gas. No exposure to oil. |
Insulation Resistance |
- 100 MΩ or more when 500 VDC megger is applied between the power supply input and frame |
Dielectric Strength |
- Sufficient to withstand 0.5 kVAC at 50/60 Hz applied between the power supply input and frame for 1 minute |
|
|
|
|
|
|